Product Description
1100-4680 m³hr Twin Lobe Blower
Highlights
| Model No. | SR295 |
| Specification | Twin Lobe Blower |
| Gear Center mm. | 152.4 mm |
| Swept Vol. Per Rev. lit/rev. | 29.5 lit/rev. |
| Air Flow m³/hr | 1100-4680 m³/hr |
| Max. Pressure m bar | 550 m bar |
| Max.Speed rpm | 3000 rpm |
Pressure Data
| Pressure RISE mbar | 100 mbar | 200 mbar | 300 mbar | 400 mbar | 500 mbar |
| Blower speed rpm | m³/h | KW | m³/h | KW | m³/h | KW | m³/h | KW | m³/h | KW |
| 1000 | 1543 | 5.6 | 1427 | 10.6 | 1341 | 15.5 | 1278 | 20.5 | 1227 | 25.4 |
| 1500 | 2402 | 8.8 | 2293 | 16.2 | 2211 | 23.7 | 2150 | 31.1 | 2099 | 38.6 |
| 2000 | 3261 | 12.2 | 3159 | 22.2 | 3081 | 32.2 | 3021 | 42.1 | 2970 | 52.1 |
| 2500 | 4120 | 15.9 | 4025 | 28.4 | 3951 | 40.9 | 3893 | 53.4 | 3842 | 65.9 |
| 3000 | 4979 | 19.8 | 4891 | 34.9 | 4821 | 50 | 4765 | 65 | 4713 | 80.1 |
Vacuum Data
| Vacuum mbar | -100 mbar | -200 mbar | -300 mbar | -400 mbar | -500 mbar |
| Blower speed rpm | m³/h | KW | m³/h | KW | m³/h | KW | m³/h | KW | m³/h | KW |
| 1000 | 1528 | 5.6 | 1881 | 10.5 | 1264 | 15.4 | 1156 | 20.4 | 1022 | 25.3 |
| 1500 | 2388 | 8.7 | 2249 | 16.1 | 2136 | 23.5 | 2025 | 31 | 1879 | 38.4 |
| 2000 | 3248 | 12 | 3118 | 21.9 | 3007 | 31.9 | 2894 | 41.8 | 2736 | 51.7 |
| 2500 | 4108 | 15.5 | 3986 | 28 | 3879 | 40.4 | 3763 | 52.9 | 3592 | 65.3 |
| 3000 | 4968 | 19.3 | 4854 | 34.3 | 4751 | 49.3 | 4633 | 64.3 | 4449 | 79.2 |
High-Performance and CustomizationThis Twin Lobe Blower is designed to meet diverse requirements with its flexible configurations and robust construction. Whether you need a V-Belt or direct coupled drive, standard or custom-sized discharge flanges, the blower can be tailored to fit your operational needs, ensuring adaptability across multiple industrial applications.
Reliable and Efficient OperationBuilt for endurance, the blower operates at working speeds from 750 to 1500 RPM, delivering stable pressure output up to 1 Bar. Splash lubrication and air cooling boost system longevity and efficiency while maintaining ease of maintenance, making it suitable for continuous, demanding use in treatment plants and conveying systems.
Advanced Safety and Low NoiseIntegrated with key safety features, including a robust safety valve and oil seal shaft, the blower ensures secure operation. With noise levels below 85 dB(A) at 1 meter and inlet/outlet silencers, its ideal for environments where noise control matters. Anti-corrosive paint further provides added durability against harsh operating conditions.
FAQs of 1100-4680 m/hr Twin Lobe Blower:
Q: How is the 1100-4680 m/hr Twin Lobe Blower installed and what are the mounting options?
A: The blower is floor mounted for stability and ease of access during operation and maintenance. Installation should be performed by qualified professionals to ensure proper alignment with the drive type (V-Belt or direct coupled) and connection to system piping, following the manufacturers guidelines.
Q: What types of industries and processes can benefit from using this Twin Lobe Blower?
A: This blower is ideal for effluent and sewage treatment plants, pneumatic conveying, water treatment, aeration, and gas boosting processes. Its robust construction and variable output make it suitable for a range of industrial and municipal applications.
Q: When should splash lubrication oil be checked or replaced in this blower?
A: Splash lubrication ensures the moving components are properly lubricated for long-term operation. Check the oil level and quality at least once a month, and replace it as per the manufacturers recommendation, typically during routine maintenance or when the oil appears contaminated.
Q: Where can the blower be flexibly used with respect to capacity and layout?
A: The blowers dimensions and discharge size can be customized as per capacity and site requirements. Its adaptable base frame allows installation in new or existing setups at treatment plants, within industrial facilities, or in outdoor environments where protection from weather is ensured.
Q: What are the benefits of the anti-corrosive coating and integrated silencers?
A: The anti-corrosive paint protects the blower from harsh chemicals and moisture, extending its life even in challenging environments. Inlet and outlet silencers significantly reduce noise, making it more suitable for settings where low sound emissions are essential.
Q: How does one determine the appropriate model and power requirement for specific applications?
A: Power consumption and blower size depend on the desired air flow rate and pressure output needed for your process. Consult your distributor or manufacturer with your application details (such as required air volume and operating pressure) for guidance in selecting the best model and power configuration.